Blog Archive

china lab waste incinerators

.Necessary tooling and gauges shall have also to be supplied.   14.Supplier shall have to arrange free training for user staff in operation and maintenance   15.Supplier shall have to provide related drawings/diagrams (civil, mechanical and electrical etc.)electrical load and electrical circuitry …

pet cremation incinerator cost

Intermittent Feed (w/optional loader): .9 yd3/hr (.7 m3/hr) up to 8 hrs/day         Specifications: Length overall -9′-6″ (2896 mm) batch system w/o loader         18′-6″ (5639mm) w/optional loader system Width overall -7′-6″ (2820mm)       …

mobile incinerator design

The Authority may require that the certificate holder have tests carried out by an accredited institution to determine stack and/or ground level concentrations of the following substances.   Cadmium and compounds as     Cd Mercury                                      Hg Thallium                                     Tl   Chromium                                  Cr Beryllium                                    Be …

manufacturer of ha zardous waste incinerator in china

?Incinerate minimum 80kg/hr X 12 hrs per day ?Disposal of both non-hazardous and hazardous waste streams (per waste inventory) ?Mobile Unit (Skid mounted preference with lifting points) Design/Specifications ?Incinerators must have a secondary combustion chamber with a minimum temperature range of 900c …
incinerator for medical waste

incinerators animal

Class 2          Industrial Incinerators Class 2A:    Commercial Incinerators for the disposal of waste that contains hazardous, potential hazardous and bio-medical waste where the operator exceeds 100 Kg/day. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h) Fully automatic computer multi control system. Fuel Options- …

medical waste incinerators china

Ensure flame contact with all gases is achieved. –yes Ensure residence time is not less than two (2) seconds. –yes Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is not …

incineration in china

Combustion Efficiency     99.99% Retention time    Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration  Of primary combustion chamber 3-6% max. Refractory    The chambers should be lined with high thermal insulating refractory bricks with suitable thickness …

medical incinerator 20kg

We are looking for small incinerators with filter (with least minimum pollution) for burning/combusting 5kg/hr, 10kg/hr, 15 kg/hr, 20kg/hr, 25kg/hr to 50kg/hr and 300kg/hr of SOLID ORGANIC DRY AND WET NON-HAZARDUOUS of any kind (including hospital wastes) per day or per hour. …
incinerator for medical waste

incinerator suppliers

1.Solidifier (Fluid waste disposal product)   Liquid Waste Solidifier for Water Based Special Features of Solidifier 2lb bottle Effectively solidifies potentially serious infectious waste quickly Quickly8 penetrates to solidify blood and body fluid to convert Gels in seconds No shaking required Retrains …

pet crematory equipment

Physical /Chemical Characteristics: Boiling Point (_F) :  N/A                     Appearance & Odor: Off white, odorless Vapor Pressure(mm Hg): N/A        Volatiles (% by weight): N/A Vapor Density (Air =1) :N/A         Evaporation Rate )n-butylacetate=1): N/A HMIS Classification : Health:1; Flammability: 1   Reactivity Data: …

incinerators 150 kg per hour

combustion chamber and one flue gas afterburning chamber. The incinerator must be able to meet the following parameters:   1.Treatment capacity of: a) 50 kg waste per hour.   2.Temperature: Main combustion chamber up to 850°C, and in the second chamber > …

incinerators 300 kg per hour

Manual autoclave with vertical loading; gravity displacement type with possibility for Vacuum.   Capacity:      Up to 12 kg/h   Chamber size:      >150 liters   Material:       Stainless steel   Temperature:       134 °C   Further information:   Minimum autoclave chamber size shall be 150 …

20kgs per hour incinerator

The manufacturer must provide a declaration that the pressure vessel is manufactured in accordance with relevant guidelines for pressure equipment.   Following accompanying documents should be supplied with the treatment system and shall be available at the Site:   1.Operation instructions (including …

china medical waste incinerator

Incinerate: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and fully insulated to withstand sea humidity …

small capacity incinerators

Capacité destructive de 55 Kg/h jour de déchets hospitaliers  avec un p?.c. i jusqu’à 3.200 Kcal/Kg 1)Type de déchet hospitalier 2)Pouvoir calorifique inférieur                                                                        3.200 kcal/kg 3)Humidité                                                                                                          20% 4)Teneur  en cendres et/ou inertes                                                                       8% 5)Capacité destructive nominale                                                                         55 kg/h 6)Volume chambre de combustion                                                                     …

waste incinerator manufacturers china

5-1- Chambre de post combustion est installée au dessus du foyer  de combustion , elle  est constituée d’un cylindre  métallique  revêtu intérieurement d’une couche d’ isolant et d’une couche de matériaux réfractaires. 5-2- Volume intérieur?: 2,1 m3 Est dimensionnée pour pouvoir  garantir  …

incinerators for sale from china

Incinerators used will be limited to daylight hours of operation. This includes shutdown, cleaning and maintenance.   Waste streams shall not be mixed during the incineration process and the ash collection chamber will be cleaned when a different waste stream is to …

medical incinerator primary combustion price

Equipped with main combustion  chamber and a second chamber  for reburning  designed to ensure  complete combustion  of the gases  resulting  from  incomplete  combustion  of inert gases in the chimney, within the standards recommended  by the World Health Organization;   Equipped with temperature …

animal cremation equipment prices

    The following requirements are to be considered as an integral part of the technical specifications for each equipment type.   The system offered shall be designed to operate normally under the conditions of different regions in Kenya. These conditions may …

medical incinerator design

It is expected that the Bidder will cooperate closely with PATH and target Hospitals for the new waste handling building/area and will make available all needed technical information, drawings, etc.,   The following waste streams shall be treated in the new HCW …

pet crematorium equipment

Finally, steam to  the jacket should shut off, the unloading door is to be opened Then the shaft and mixing arms are reversed to act as unloading mechanism and should scoop the waste fragments out of the unloading door, onto a conveyor …

small incinerator for sale

Sterilization time: approx. 30 minutes at 121◦C/1.1 Bar or approx  15 minutes at 132◦C/2.5 Bar to achieve 6log10 sterility Fragmentation inside the chamber: Heavy duty with maximum size of final product <20 cm. Volume reduction of the waste after processing : by …

incinerator for medical waste

Lifting Chains: Must be dual lifting chain of roller style & must meet safety factor at least 6:1. Hydraulic System: Durable cylinder with a chrome plated ram and a relief valve for overload protection Forks: Heavy duty steel approx. 4.0” wide x …

incinerator 500kg per hr

The secondary combustion chamber must destroy the contaminant product and must resist to high temperature(1100 °C)   Process Filtering system: Scruber to be mentionned as optional Emission Standards Compliance: BS 3316 or équivalent standard Version , the entire carcass of animals ( …

red bag waste incinerator

“Waste chamber Chamber capacity 300 kg Chamber volume .54m3 Chamber size (outside) Width: 91cm, Height: 86cm Length: 152cm Door opening 66 x 76 cm Height to door 84 cm Height to top of stack 5.4 m Suggested slab size (L x W …

medi burn 30 contraband incinerator

air retention for at least 2 seconds at a temperature of less than 850C, the combustion In order to achieve the proper effect. ? must be a two-chamber incinerators, primary and secondary Fuel stoves ? The waste products to reduce the initial …

medical small incinerator

Dimensions: World standard: 0.83m(I) x 1.0m(w) x 1.4m(h) Burning efficiency: >98% china double chamber incinerator Features: ?     Waste type and burn rate: Designed specifically for use by poultry farmers, game-keepers and for pet cremation. The incinerator will burn up to 50 kg …

medical waste heat value

18   Electrical supply required 3-phase 19   Auxiliary fuel      Diesel or paraffin 20   Primary burner 21 Secondary (after) burner 22 Type of burners   Automatic pressure jet 23   Output Primary   Approx 600 000 kJ/hour 24   Output Secondary      Approx 750 000kJ/hour 25 Emission control Heated …

medical incinerators in china

Would plant operations be operational on a basis of 24 hours per day, 7 days a week, all year long except for regular and preventive maintenance periods?   How many hours per year could your process be operational?   What would be …

incinerators from china

An operating test should be conducted to ensure that all of the control components have been properly installed and that all parts of the incinerator, including controls and safety devices, are in satisfactory operating condition. The requirements for prepurge and time between …

pet cremation incinerators

The successful bidder shall deliver the incinerator skid in a container. The container will be emptied by CEB and returned to the successful bidder / or to its shipping agent. A containerized solution is also acceptable. Electrically operated 220 volt ( 60 …

incineration combustion chamber

Supervision of installation of the new incinerator set shall be provided by the successful Bidder while labour and heavy duty equipment shall be provided by CEB.     ?     The successful Bidder shall submit to CEB, prior to shipment of the incinerator …

smart ash incinerator price

Flue Gas Cleaning   System   ? Wet Scrubber   ? Electrostatic precipitation in combination ( Optional: Rate to be   quoted separately)     7 Chimney Height 10m (minimum)       ?     Total duration of the supervision of installation, testing …

animal incinerators china

Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency …

animal crematorium equipment

I also research their product details and find it don’t require fuel and also not require fan blower but that incinerator can only burn waste with 30%-40% humid. I see if your products can burn waste with 30%-40% humid without fan blower …

large scale incinerator

Programming controls. Programming controls should be verified as controlling and cycling the unit in the intended manner. Proper prepurge, ignition, postpurge, and modulation should be verified. A stopwatch should be used for verifying intervals of time. ?     Fuel supply controls. The satisfactory …

incinerator burners

Fully automatic sequential control provided by internal PLC system providing control of: Secondary chamber pre-heat Burn cycle (variable) Cool down cycle Fuel Options Diesel, LPG, Natural or Bio Gas. Typical Fuel Consumption Diesel: 8 / 10 litres per hour Liquid Propane Gas: …
INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

hospital incinerator manufacturers

The incinerator fuel tank shall meet the following requirements: a) The tank shall be installed above ground and according to all of the fuel tank requirements in Section 1015 including secondary containment. b) The tank shall be sized to hold a 14 …

hazardous waste incinerators in china

Anchor all equipment to building floor or structure as shown or as recommended by manufacturer with allowance for thermal expansion as necessary.   Control and Instrument Panel: Rigidly attach enclosure to structural element of the building. Locate panel so that all control …

incinerator capacity calculation

Test shall be conducted by factory authorized representative of incinerator manufacturer.   Demonstrate required weight reduction of specified waste. Waste shall be fed in a single batch to the unit. After termination of manufacturer’s predicted burning period, inspect and weigh the residue. …

incinerators manufacturers china

The incinerator shall then take supply from the DO tank through its DO feed pumps to its respective burners. An integrating meter shall be installed to measure the volume of DO consumed by the incinerator. Suitable pre metering strainers shall be provided …

medcial incinerator manufacturer

The successful Bidder shall inform CEB in writing at least three (3) weeks prior to the carrying out of factory tests so as to enable sending of one CEB Engineer for witnessing  of  the  factory  tests.    A  ‘Factory  Acceptance  Test ’  schedule  …

msw incinerator manufacturers

standard type, 11m long ,self supporting Capacity-220kgs/hr refuse-hospital waste average moisture-15-20% on fist time DIMENSIONS height: 2710mm length: 2840mm Width; 2450mm loading door opening: 610mm x 610mm Grate/Heath Area: 2.0(square meters) Primary chamber volume: 2.4(cubid  meters) secondary chamber volume :2,72(cubid meters0 total …

pet animal cremation equipment

A chamber of post combustion of gases * A burner of combustion of gases, * A device of injection of air allowing a total recombustion of gases, * A device of air inlet of cooling of waste gases, * A sheath of …

small home incinerators

Equipment Access Openings: Arrange all equipment and piping to allow access to openings without disassembly of equipment or piping. Provide space which permits full opening of all doors, panels, and other access openings.   Operating Space: Do not reduce or alter personnel …

small incinarator

heavy Duty Steel casing   High Quality refectory lining & insulation   1 x Diesel fired ignition burners operated on / off   Front Loading Door (safety catch   Separate Ash removal Door     2.7  CONTROL UNIT   The entire processing …

pet crematory

The temperature is over the minimum and under the maximum required temperature (e.g 1150?C) of the thermal reactor (partial load).   When switching off, only the solenoid valve for the fuel supply closes, the burner fan stays on to cool and protect …

hog incinerators

The purpose of the start-up burner is to ignite waste materials and to maintain the prescribed minimum temperature in the primary chamber. It shall be mounted in the lower part of the primary chamber.   The start-up burner shall function automatically when:- …

hog incinerator

(B) Features and Specifications  of the Steam Boiler: Features of the Boiler: It must be an Electrical boiler Splash proof electric enclosure and switches Door Isolator to main electric enclosure Alarm lights and Safety/protection against excel pressure Level control on feedback water …

animal cremation

Technical Specifications of External SHREDDER Controls: Pre-programmed PLC controlled Password activated and reversal history indication Motor starter with overload protection Automatic instantaneous stop on hard object in shredder bed Automatic heavy cutting load reversal and re-try , up to three times Control …