(G) Technical Specifications of Spore tester Features and Specifications : It is an auto reader for Bacillus Stearothermophilus to test the spore discharge after treatment (sterilization) of the waste. should be a very Accurate, reliable and easy-to-use units for reading rapid readout …

domestic incinerator

Documents to be submitted as following ; Fabricators accreditations Test report to prove ZERO harmful emission level provided as samples form other installations Test report to prove sterility achieved at 6log to 10 level to be provided upon commissioning report and validation. …

medical waste

———————————–   Failure to establish the authenticity of the certificate the bidder is liable to render the bid non-responsive and bidder open to action in the line with applicable regulations and act. Original catalogue must be submitted Original data sheet must be …

small incinerators

The incinerator shall be equipped with water injection nozzle connection. If the temperature in the primary chamber should rise too high (normal temperature between 300 and 800?C) during the operating time, the automatic water injection shall be activated to decease the temperature. …

animal incinerator for sale

The incinerator shall be provided with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork shall consist of refractory lined tubes and high temperature resistant tubes made from rolled sheet steel of minimum …

medical waste furnace

The incinerator to be fully assembled wired and logic function tested in the factory, prior to dispatch.   –      One high flue gas temperature indicator/alarm to provide an audio/visual warning in the event of high flue gas temperatures occurring in two stages:- …

small scale medical incinerator

The burners shall comply with the requirements of BS 799 or DIN Standards. Each shall be the packed type and incorporate automatic stop/start programmed timer control, flame failure equipment and ignition failure equipment to close off the fuel supply in the event …

incinerator smoke filter

All particles of the waste should achieve a high level of sterilization and not just “disinfection” due to the continuous agitations Description of the Treatment Cycle of the processor i) Loading * The waste has to be loaded by dropping bagged and …

animal incinerator china

Medical Waste Shredder    Capacity: Should be 150 liters.  Should be capable to shred up to 100 liters of the treated waste. 7  The technology should be capable to treat hospital waste including sharps like needles, lancets, scalpels and …

incinerators

The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by basic designation only. A1) Technical Specification: Incinerators All types of diesel fired incinerators suitable for HCW may be offered as …

small animal incinerator

Piping and stack connection locations and sizes.   Technical data including temperature rating and arrangement of refractory and insulation.   Weights of unit and loading diagram of foundation. Evidence that contractor has coordinated support requirements with foundation design.   Recommended anchorage to …

animal incinerators

The incinerator shall be equipped with a Diesel oil tank that will be supplied with DO from our DO tank located in the power station. The tank shall be equipped with level switches and appropriate solenoid valves for automatic filling of the …

pet incinerator prices

Spare part list –After burners Item description                                                No of required Motor     2 Control box  2 Pump couplings   4 Photo cells    2 Sets ht. leads       2 Sets electrodes    4 Oil valve       1 Nozzle   2   Spare part list –Ram loader Item description                                                No …

incinerator installation demo

The switchboard shall operate in a room with the following prevailing conditions:   –      Maximum ambient temperature of 40 0C –      Maximum relative humidity of 95% –      Saline atmosphere –      Altitude: at sea level –      Climate type: Wet and humid coastal conditions …

pet incinerators

  The panel and parts hereof shall have the following characteristics:         Finish   All metal parts shall receive a treatment taking the prevailing environment conditions into account.         The top paint colour shall be the …

incinerators china

All numbering will be carried out in compliance with the corresponding circuit diagrams and wiring list.   Component Marking         All components inside the switchboard shall be marked for identification.         The  marking  shall  be  effected  …

medical waste incinerators

All labels with text shall be in English.         Anti-Condensation Heaters         The Panel shall be provided with a thermostat controlled anti-condensation heater 240 V, 50 Hz.         Earthing System   All normal …

animal incinerator manufacturer

Spare part list- ignition burner Item description                                                No of required Motor     2 Control box  2 Pump couplings   4 Photo cells    2 Sets ht. leads       2 Sets electrodes    4 Oil valve       1 Nozzle   2   Parameter Compliance Type of Waste To treat medical …

animal incinerator cost

    The incinerator shall be able to incinerate both liquid and solid as per data below;     Liquid waste to be incinerated   The sludge to be incinerated is composed exclusively of a water and oil mixture in any proportion …

incinerator manufacturer china

The sludge shall be properly atomized by means of compressed air in the burner so as to ensure complete combustion of the sludge.     An air compressor complete with a receiver shall be included in the incinerator. Both compressor and receiver …
incinerator operation video

laboratory incinerator china manufacturer

Solid waste to be incinerated     Cartons,  rags,  cotton  and  other  wastes  associated  with  generation  of  electricity loaded in the incinerator in bags. Loading capacity: At least 100 Kg / h     Start up fuel     Diesel Oil   …
incinerator for medical waste

large animal incinerators

The incinerator shall also be equipped with special loading devices and mechanisms that allow safe incineration of solid waste simultaneously with liquid sludge. Loading of solid waste may be achieved through bags.   All intermediate piping, bellows and other fittings for connection …

china animal cremation

The panel shall comprise of a compartment for the connection of power and control cables. Passage for power cables and control cables shall be made by the bottom part of the switchboard.         The drawer shall be locked in …

china incinerator

Stack size shall be in accordance with the manufacturer’s recommendations. Stacks shall be the forced-air type and   completely self-supporting and unattached to nearby structures. As a minimum, stack heights shall minimize   downwash of stack emissions due to aerodynamic influences from …

incinerator china

oElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. Controls and regulations: Control box watertight to dust, including:   A switch circuit breaker for each engine (ventilators …

animal incinerator

Logic Programmed Control of 2 Burners Range Of Pre-Set Burn Times Fuel Saving Burner Efficiency Control Program with Constantly Running Fans Temperature Monitoring With Separate Displays for Primary/ Secondary Chambers Auto Control Manual Control Timer Control 0-24 Hours Integral Fun Timer Control …

animal incinerator price

This Server Pack (Supplied As Part of the Machine) Constitutes Sufficient Parts to Maintain the Machine Adequately For A 3 Years; the Parts in the Kit Mainly Related To Diesel Fired Burners and Are As Follows;   Thermocouple Temperature Sensor -2 Burner …

small incinerator

Capacity 100 kg/hr of waste containing up to 85% moisture   ?      Two combustion chambers   Two fully automatic, oil fired, pressure jet burners   Panel board   Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.   …
incinerators

pet incinerator deisel

and forced air exhaust stacks (or chimneys).   The charging system shall consist of, as a minimum, a hopper for top feeding and mechanically operated hydraulic   charging ram or augur. To prevent warpage or excessive thermal expansion, a charger cooling system …

30 kg per hour-incinerator

Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to   oxidize (or burn) the organic vapors and gases. Burner and combustion air controls shall be fully automatic Diesel incinerator of 25Kg / h     …

pet incineration equipment

Minimum capacity: 500L Provided with supporting structure valves Level indicator tank funnel Filter impurities in the mouth of the tank     Especifica??es técnicas   Incineradora a Diesel de 25Kg/h     Caixa Dimens?es da caixa do incinerador.   Largura aprox: 900 …

portable incinerator manufacturers

Tanque Capacidade mínima: 500L Provido de estrutura de suporte Válvulas Indicador de nível de tanque Funil Filtro de impurezas na boca do tanque     comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe …

incinerators for sale

chamber and burner shall be designed to maintain a minimum combustion temperature of at least 760 to 870 C   (1400 to 1600 F). The ash-removal system shall consist of the automatic continuous removal of the ash into an ashquench   pit …

crematorium manufacturers

Doors The doors shall be hinged on the right hand side and can be easily opened and closed. All doors shall be manually operated. Incinerator shall NOT incorporate automatic doors. All doors should be internally lined with pre-determined thickness insulation and refractory …

hog insinerators

Finish All equipment shall be painted with a coat of zinc rich primer and two coats of high temperature heat resistant polyurethane type paint. All painted surfaces shall be prepared by either steel shot cleaning or sand blasting.   Identification and Name …
INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

small medical waste incinerator

i- burners: use diesel , natural gas , liquefied petroleum gases according to standards burners should have main vent to be used for protection. 2- materials: -the chamber should be covered from inside with refractory brick with thickness 22 cm aluminum silicate …

incinerator manufacturers china

Ash should be only 5% of the waste material   Weight of Incinerator – 50-60 Kg Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories, complying with 01015 par. 5.16.1 LOT 2.0   Medical incinerator with …

animal waste incinerator

secondary chamber 1000 degree   chimney standard   shredder separately   Autoclave or microwaves separately   temperature monitor attached outside of machine   operating Fuel and electric During the start and end incineration operations at the waste incineration plant the temperature shall …

pet cremation equipment

Waste Incinerator Capacity The waste incinerator units shall be designed to burn medical waste load of capacity 50 kg/hr with calorific values ranging from 2,300 kJ/kg to 30,000 kJ/kg at a designed thermal rate of 1,440,000 kJ/hr.   Method of Waste Charging …

incinerator 500kg per

Composition of the refractory lining: * Insulation: – Operating temperature:                1000 ° C max – Nature:                                   Calcium Silicate – Thickness:                              80 mm * Refractory: – Operating temperature:                1650 ° C max – Nature:                                   Refractory bricks with 42 alumina – Thickness:                              …

pet incinerator for sale

We are looking at a simple incinerator which should be fired using domestic LPG bottles. Other sources of ignition can be considered as well but we need to keep it simple.       Section VI. Requirements 2-86     required for …

incinerator

l) Ease of Use and maintenance i) The unit should be simple to learn to use, operate, and maintain. ii) The unit should have abbreviated operating instructions included on or with the unit (e.g., on a laminated card attached to the unit). …

pet incinerator price

j) Controls i) The controls (i.e., switches, knobs, etc.) should be visible and clearly identified, and their functions should be self-evident. ii) Device design should prevent misinterpretation of displays and control settings. iii) Switches and controls should be protected against accidental setting …

mobile incinerator china

Temperature:  ambient temperature ranges between 21 – 450  C or more in poorly ventilated rooms. The hottest month of the year is March. Environmental temperature can be such that inferior rubber and plastic materials can easily melt or deformed. Bidders must ensure …

garden incinerator

c) All manuals must be in English language.   9)  Each of the equipment supplied must be provided with user and technical manuals. Instructions on their usage, storage and service must be clearly indicated in the manuals and where necessary, on the …

300 kg incinerator

i) Patient and operator safety and system performance should not be adversely affected by fluid spills. ii) If the unit is affected, it should fail safely.   c) Overcurrent Protection i) Loss of power to other equipment on the same branch circuit …

animal crematory equipment

ii) The visual alarm must be specific to the problem and remain on until the alarm condition is corrected; it should not be possible to turn off the visual alarm.   i) Construction Quality i) The unit should have no sharp edges. …

china incinerator supplier

f) Alarms i) The unit should have visual or audible alarms to warn operators of any system fault that may cause unsafe or erroneous results. ii) Audible and/or visual indicators should activate when the display reading reaches and remains at the alarm …

hospital waste incinerator

  Height: 82″ (208 cm) without stack, 100″ (254cm) with stack Width:  39.5″ (99 cm) burn chamber, 58″(147cm) at base Length: 62″ (157 cm) overall, 34″(86 cm) at base Weight: 1800 ibs (approximately 816 kg)   Primary Chamber Volume: 10.5 cu.ft. (.28 …

medical incinerator prices

INCINERATOR WITH CONTROL UNIT Has been specifically designed for use in: – Hospitals – Clinics – Laboratories – Disaster relief Operations – Animal Cremation – Can be used to eliminate medical waste with reliable, on site technology   An innovative system for …