Technical specification for burning incinerator machine

17.The primary burning room  should have at least 2 burners.
18.The secondary burning room should have one burner.
19.  Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for maintenance.
20.Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank should have capacity of 1000 
lt and should be fixed to the system and provided with water level indicator.
21.Each system should have special technology for separating waist products and humidity after gas processing.
22.Each system should have cooling capability after operation.
23.Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust system should be 1000 mm. 
The exhaust pipe should be 6 mm and should be provide with heat insulator.  The exhaust system should be provided with pressure indicator. It 
should also provide with ladder and Lightning Arrestor.
24.Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP.
25.Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The control panel should 
show at least temperature in both the primary and secondary rooms and injectors of the filters and load.   
26.Each system should be provided with alarm system for any breakdown or defect of any component of the system.
27.The following personal protective tools must be provide:
a.Heat resistant garments for 20 persons.
b.Heat resistant goggles for 20 persons.
28.All components of each system should be painted with silver color that is heat resistant.