medical incinerator manufacturers

All solid wastes must be transferred to storage pit from Transit and Sorting Center. Solid wastes storage pit is input

of rotary kiln.

All fluid wastes must be stored and stabilized in Transit and Sorting Center. All storage and stabilization devices or

facility must be considered. Storage and stabilization devices (facility) consist of:

Tanks, Pumps (Transfer, Loading & Unloading), Agitator (Mixer), Blanketing System, Flare system, Instrumentation and

Control Systems, etc

Storage and stabilization capacity must be considered based on worst case (shut down).

Generally incinerator plant consists of two similar trains (capacity of each train is 100%). Each train consists of a

rotary kiln and a static kiln.

Based on client request, efficiency of incinerator plant is 99.8% for all components and for aromatic must be higher

than that amount.

Please be attention, produce high pressure steam from output heat of incinerator plant is in this scope of work.

 

Burner operation should be Automatic On/Off

Fuel?: diesel

 

Manufacturer to provide  necessary information for the best of  the installation

 

 

The control panel shall have all appropriate audible and visual alarms to ensure safe operation.