Waste Incinerators

HICLOVER|Medical |Environmental|Pet Animal
Menu
  • Home
  • About Us
  • Products
    • FAQs
  • Hot Sale
  • Project Case
  • Blog
    • Incinerator Video
  • Contact Us
    • Sitemap
    • Eblogs
    • 中文网站
  • Containerized diesel fueled incinerators

  • emissions Directive 2000/76/EC

  • small incinerator

    a pet incinerator for the cremation of dogs

  • pet cremation incinerators

  • hog insinerators

  • animal waste incinerator

  • Incineration of biomedical waste

  • Baghouse filter in a circular design, with automatic pulse-jet cleaning system of the filter bags

  • Hypocritical Smoke: The Scandal of Medical Waste Incineration

  • INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

    Gasified incineration for burning medical wastes incinerator

  • Pet Animal Cremation Machine

  • SHARP MEDICAL WASTES

    SHARP MEDICAL WASTES

  • Evaluation of Vendor offer for Solid Sludge Waste Incinerator

  • 3 Chamber Incinerator

  • waste incinerator manufacturers

    waste incinerator manufacturers

  • Medical Waste Incinerator of 20 kg/hr capacity with dual burner

Incineration of biomedical waste

– intended to destroy and without polluting the environment, biomedical anatomical solidand non-anatomical waste‑ Smoke burning incinerator with a total volume of combustion chamber of approximately1 m3 (± 10%), with manual waste loading via a front door with an inspection flap (to check the flame)  eliminatory‑  First combustion Chamber: more than 60% of the total volume‑  Post combustion Chamber (burning of smoke): Up to 40% of the total volume‑ Interior lining of chambers made of refractory material (nature to be indicated) making itpossible to reach and maintain a temperature up to 1000 °C eliminatory– Forced air Convection (by motorised Fan kW maximum) eliminatory– automatic cycle of maintaining the working temperature (burner control)– Insulating Layer (nature of the materials to indicate) between the combustion chamberand the exterior metal structure, including loading door (less than 60 °C on the frame in anormal regime), heat resistant layers of external protection – Calorific power required: 115 to 150 kW (418,000 to 543 400 kJh-1)– automatic illumination burners (electrical or piezoelectric) with security of flamepresence eliminatory– heating oil supply (diesel): 8 litres/hour maximum– Fuel Injection pump for 1 kW maximum– autonomy Tank of approx. 150 litres fitted with a booster pump– An expansion chamber provided with an ambient air intake flap located in the flue/burntgases path reduces the gas ejection velocity and dilutes it– The discharge into the atmosphere should be free of the following (results certified by amonitoring body acceptable by the purchaser): carbon monoxide (CO <0.1%), nitrogen oxides (Nox) and carbon (<8%), unburned fuel and hydrocarbons (<0.3 ‰), solidparticles (<7%).– Front or side control box comprising:     * on switch     * Getting started      * Emergency stop      * Choice of cycle (manual or automatic)      * Choice of working temperature      * Choice of cycle time      * Ventilation      * Priming of burners* Operation and phase indication indicators (presence of flame, temperature, time, fan, endof cycle, fault alarms, on / off, …)Safety devices :– Flame presence security: stop and alarm after several unsuccessful attempts to sparkEliminatory– overheating safety: fuel cutoff in the event of excess temperature Eliminatory– Security all closed doors (except possible inspection door)– Fuse protection– Disconnector to completely isolate the device during maintenance. Spare parts to provide:– 01 door seal– 01 set all of the light indicators– 01 set of all thermocouples– 02 sets of the nozzles of the burners– 01 set of ignition systems of the flames– 01 set of coils of all switches– 01 set of coils of all solenoid valves– 01 replacement kit for the fuel injection pump – 02 sets of all protection fusesEach equipment will be supplied with:– the local – 01 fireplace – 01 ash tray with a displacement scraper– 01 kit for cleaning the nozzles of the burners– 01 adapted manual igniter (in case of automatic ignition failure)– Electrical box for mains connection with at least one modular circuit breaker of suitablesize– 02 powder fire extinguishers (with their wall hangers)– 01 maintenance kit-1 UPS of adequate power-1 voltage stabilizer with recovery  time – All the other accessories necessary for the proper functioning of the equipment– 01 user and maintenance manual in French

Baghouse filter in a circular design, with automatic pulse-jet cleaning system of the filter bags

3 Chamber Incinerator

Evaluation of Vendor offer for Solid Sludge Waste Incinerator

Blog

Containerized diesel fueled incinerators

Incinerator Type: Containerized, diesel fueled Burning Rate:100–120kg/hour Minimum Operating Temperature:850o C(primary combustion) Maximum Operating Temperature:1450 oC(Afterburner chamber) Secondary Burning Capacity:Compulsory Density …

emissions Directive 2000/76/EC

small incinerator

a pet incinerator for the cremation of dogs

We have a 70 bed hospital in namibia. however there is a potential of getting customers from other local doctors. a …

pet cremation incinerators

The successful bidder shall deliver the incinerator skid in a container. The container will be emptied by CEB and returned to …

hog insinerators

Finish All equipment shall be painted with a coat of zinc rich primer and two coats of high temperature heat resistant …

animal waste incinerator

secondary chamber 1000 degree   chimney standard   shredder separately   Autoclave or microwaves separately   temperature monitor attached outside of …

Hypocritical Smoke: The Scandal of Medical Waste Incineration

The middle-class Foxboro subdivision in North Salt Lake City, Utah, is, in many ways, an idyllic community for young families – …
INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer

Gasified incineration for burning medical wastes incinerator

Gasified incineration for burning medical wastes. Fuel type: Natural Gas Burning Capability: –     30-50 kg/time –     Daily 3-6 times Incinerator size:  …

Pet Animal Cremation Machine

We have Family pets, after they are dead, the best way for pet dog, cat is cremation. The farm animal, dead …
SHARP MEDICAL WASTES

SHARP MEDICAL WASTES

A SET OF INCINERATOR FOR DISPOSAL OF SUCH HOSPITAL SHARP WASTES LIKE THE NEEDLES,SYRINGES,CUTTERS, BLADES, ETC. WASTE BUCKET/TANK – ABOUT 2000KG …

Incinerator Video

Incinerator Operation Video

clover medcial yz model incinerator video

Small Scale Incinerator Operation Video

Small Scale Incinerator Operation Video

HICLOVER Incinerator YDC model small scale incinerators

    Recent Posts

    • Small Scale Incinerator Operation Video
      Small Scale Incinerator Operation Video
    • INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer
      Medical Incinerator Installation and Operation Video
    • Containerized diesel fueled incinerators
    • small incinerator
      a pet incinerator for the cremation of dogs
    • emissions Directive 2000/76/EC
    • pet cremation incinerators
    • animal waste incinerator
    • hog insinerators
    • Baghouse filter in a circular design, with automatic pulse-jet cleaning system of the filter bags
    • Incineration of biomedical waste
    • INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer
      Gasified incineration for burning medical wastes incinerator
    • Hypocritical Smoke: The Scandal of Medical Waste Incineration
  • a pet incinerator for the cremation of dogs
    small incinerator
  • Containerized diesel fueled incinerators
  • emissions Directive 2000/76/EC
  • animal waste incinerator
  • pet cremation incinerators
  • hog insinerators
  • Pet Animal Cremation Machine
  • Hypocritical Smoke: The Scandal of Medical Waste Incineration
  • Gasified incineration for burning medical wastes incinerator
    INCINERATEUR COMBUSTION DESTRUCTION OF MEDICAL WASTE PYROLYTIC AND LABORATORY,incinerator medical waste manufacturer
  • SHARP MEDICAL WASTES
    SHARP MEDICAL WASTES
  • Medical Waste Incinerator of 20 kg/hr capacity with dual burner
  • waste incinerator manufacturers
    waste incinerator manufacturers
Waste Incinerators Copyright © 2025.
Powered by HICLOVER