mobile incinerator design

The Authority may require that the certificate holder have tests carried out by an accredited institution to

determine stack and/or ground level concentrations of the following substances.

 

Cadmium and compounds as     Cd

Mercury                                      Hg

Thallium                                     Tl

 

Chromium                                  Cr

Beryllium                                    Be

Arsenic                                       As

Antimony                                    Sb

Barium                                        Ba

Lead                                            Pb

Silver                                          Ag

Cobalt                                         Co

Copper                                        Cu

Manganese                                  Mn

Tin                                               Sn

Vanadium                                     V

Nickel                                           Ni

Hydrochloric                                HCL

Hydrofluoric acid                         HF

Sulphur dioxide                           S02

 

  1. A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in

the waste feed where:

 

DRE = [(Win – Wout)/Win]*100

Where: Win = mass feed rate of the POHC in the waste stream fed to incinerator, and

Wout = mass emission rate of POHC in the stack prior to the release to the atmosphere.

SOLID WASTE INCINERATOR

1

ea

 

 

1.5 MMBtu / hr waste combustion, providing 200-250 lb/hr (90-114 kg/hr)

 

 

 

 

Processing capacity for mixed waste streams with an average gross

 

 

 

 

HHV of 5500-8500 Btu/lb

 

 

 

 

Batch Operation: Approx. 1.9 yb3 (1.45 m3) per 4-6 hour operation cycle